MIL-PRF-131K Type I Class I
Structure: OPP/PE/Foil/PE
Meets all of the requirements of MIL-PRF-131K, Class 1. Intended for applications requiring a flexible, heat-sealable barrier material with low MVTR. FR-2175 can be fabricated into pouches and used for protection of extremely critical items and materials. DMF#14943
Structure: OPP/PE/Foil/PE
Meets all of the requirements of MIL-PRF-131K, Class 1. Intended for applications requiring a flexible, heat-sealable barrier material with low MVTR. FR-2175 can be fabricated into pouches and used for protection of extremely critical items and materials. DMF#14943
Unit of Measure
Specifications
Brands |
N/A FR 2175 |
Mil Spec |
N/A Mil-PRF-131 Class 1 |
Typical Caliper |
N/A 5 mil |
Typical Tensile Machine Direction (MD) |
N/A 34 lb at break |
Typical Tensile Cross Machine Direction (CD) |
N/A 29 lb at break |
Test Method (Tensile Strength) |
N/A ASTM D-882 |
Typical Puncture Resistance |
N/A 15 lb |
Test Method (Puncture Resistance) |
N/A FED TM2065 |
Typical Seal Strength 375 Degree Fahrenheit (ºF): 26 Pound Per Square Inch (psi): 1 Second (sec) |
N/A 10 lb/in |
Test Method (Seal Strength 375 Degree Fahrenheit (ºF): 26 Pound Per Square Inch (psi): 1 Second (sec)) |
N/A ASTM D-882 |
Typical Tear Machine Direction (MD) |
N/A 64 g |
Typical Tear (XMD) |
N/A 64 g |
Test Method (Tear) |
N/A ASTM 689 |
Typical Moisture Vapor Transmission Rate (MVTR) |
N/A 0.0006 g/100 in²/24hrs |
Test Method Moisture Vapor Transmission Rate (MVTR) |
N/A Mocon |
Typical O2TR |
N/A 0.0006 g/100 in²/24hrs |
Test Method (O2TR) |
N/A Mocon |
Typical Yields |
N/A 5400 in²/lb |
Standard Sized |
N/A 36" x 1000ly 48" x 1000ly |